• Express delivery

  • Engineer-to-engineer support

  • Hassle-free returns

  • Volume pricing available

Eliar  |  SKU: ICT200-D0W-S2-C50

ICT200 - Chemical (Bundle)

Regular price €1.044,00

Inductive conductivity transmitter optimized for direct chemical concentration measurement across a wide 0–500 mS/cm range. Electrode-free sensing eliminates fouling and drift in aggressive process media, while wireless commissioning via EliarSmart enables fast setup in hard-to-reach installations.

Product Highlights

📏
Customizable
Range
🛜
Wi-Fi and Bluetooth
Connection
🌡️
140 °C
Max Temp
🔌
2× 4–20 mA
Outputs
🛡️
PEEK
Wetted Material
💧
IP67
Protection

Product Details

Inductive conductivity transmitter for chemical concentration measurement in demanding industrial processes. Designed for reliable monitoring in aggressive media, elevated temperatures, and installations where access to the measurement point is limited or maintenance is difficult.

ICT200 is engineered for robust operation in harsh chemical environments where traditional contacting sensors suffer from fouling, drift, and frequent recalibration requirements.

Its inductive (toroidal) measurement principle eliminates electrode contact with the medium, preventing fouling and ensuring long-term signal stability even in continuously changing process chemistry.

Wide 0–500 mS/cm measurement range is optimized for medium-to-high conductivity applications, providing accurate concentration monitoring without unnecessary range complexity. This makes it well-suited for process tanks, dosing systems, and chemical storage or circulation loops.

The integrated 2.8” touchscreen provides real-time conductivity, concentration, and temperature readings directly at the installation point. Dual isolated 4–20 mA outputs enable transmission of conductivity (or concentration) and temperature to control systems.

Built-in concentration tables provide direct weight-percent measurement for common chemicals such as NaCl, NaOH, Na₂SO₄, and H₃PO₄. Custom concentration tables can be configured for application-specific process fluids.

Commissioning is simplified through the EliarSmart mobile application, enabling fast setup and configuration without direct access to the device in hard-to-reach locations. Wi-Fi communication capability reduces cabling requirements and allows flexible integration into modern control architectures.

Ideal for: 

  • Chemical storage tanks
  • Dosing and mixing systems
  • CIP and cleaning circuits
  • Water and process lines
  • Hard-to-access industrial installations
  • High-conductivity chemical processes
  • Salt dissolving units
  • Caustic (NaOH) preparation and dilution systems
  • Concentration control in high-conductivity chemical processes
Measurement Principle Inductive (toroidal / electrodeless)
Conductivity Range 0–500 mS/cm (S2, single range)
Conductivity Accuracy ± 0.5%
Repeatability 0.2%
Temperature Compensation Solute-specific matrix-based, linear, non-linear TC curve, custom table
Temperature Sensor Pt1000, Class A
Temperature Range -20 to 140 °C
Temperature Accuracy ± 0.3 °C
Concentration Output NaCl 0–25 wt% · NaOH 0–15 / 20–50 wt% · Na₂SO₄ 0–40 wt% · H₃PO₄ 0–15 wt%
Density Output NaCl, NaOH, Na₂SO₄ in Baumé
Analog Outputs 2× 4–20 mA, electrically isolated, 12-bit, 500 ms sampling
Switch Outputs SSR 1: 100 mA @ 24 VDC · SSR 2: 200 mA @ 24 VDC
Digital Input Sinking, IEC 61131-2 Type-3
Wireless Wi-Fi and Bluetooth
IO-Link Not included in this variant
Power Supply 18–30 VDC, max 3 W
Electrical Connection M12, A-Coded, 4-pin
Display TFT-LCD, 2.8", Resistive touch
Wetted Material PEEK
Enclosure PA6-GF15
Seals EPDM, TPE, NBR
Process Connection Tri-Clamp ISO 2852 1½" (C50)
Protection IP67 (IEC 60529)
EMC IEC 61326, Class B
Weight Approx. 0.76 kg

Wiring and integration notes.

Need a custom configuration? Talk to our engineers.

Process specialists respond to technical enquiries within one business day.